LFO depth control
LFO → IN A · UNI mode · dial amount with knob · OUT A → filter CV
Dual attenuator/attenuverter/mixer in 1U format. Each channel switchable between unipolar attenuator and bipolar attenuverter. No input defaults to +5V DC. Channel A has 2x voltage multiplier switch.
Reduces CV amplitude for subtle modulation. Ideal for scaling LFO depth before sending to filter or VCA CV inputs.
Inverts a signal (e.g., turns an ADSR into a falling envelope for inverse VCA or filter control).
Channels A and B are summed at OUT B, enabling two CV sources to control one destination.
With no input, knob generates -5V to +5V DC (or -10V to +10V with Ax2). Useful for pitch offsets or static CV.
| Channel A | Attenuator A | Scales channel A input voltage. Behavior depends on Polarity Switch A setting. UNI: 0–unity · -/+: invert to unity (noon = zero) |
| Channel A | Polarity Switch A | UNI: standard attenuator (0 to full). -/+: bipolar attenuverter (invert to unity, noon = zero). No input → +5V DC internal source |
| Channel A | Ax2 Switch | Doubles the voltage at Channel A's input. Enables +10V or -10V DC offset generation. Up = x2 active · works on internal +5V too (gives ±10V) |
| Channel B | Attenuator B | Scales channel B input voltage. Behavior depends on Polarity Switch B setting. UNI: 0–unity · -/+: invert to unity (noon = zero) |
| Channel B | Polarity Switch B | UNI: standard attenuator. -/+: bipolar attenuverter. No input → +5V DC internal source |